1.two.two Warning Labels Warning Labels That means Be sure to very carefully read this handbook before use unit. The following labels can be a. Usually do not location the device on a sloped surface. If not the available when the process device could slide, resulting in individual harm or even the gadget operates Using the cell malfunction.
Greatest four occasions tasking for one particular transmitted beam, causing great time resolution and better frame fee.
Notice: Over the monitor, the brightness adjustment arrives right before distinction. Just after readjusting the monitor’s distinction and brightness, change all preset and peripheral settings.
Usually do not use any cables other than the cables presented with the machine by Mindray. 3. Use the cable offered with this system to connect the printer. Other cables may well lead to electrical shock. Website page fifteen: Mechanical Safety
By continuing your go to on our Site, you're consenting to our utilization of cookies. Even so, you may transform your cookie configurations at any time. Cookie preference Settle for and Proceed
Mindray’s new technology of black & white ultrasound technique, DP-fifty Expert, is provided with Highly developed imaging technologies letting deeper penetration and a lot quicker image acquisition with better resolution.
Webpage 145 Clean up control panel Applications: dry delicate cloth, mild soapy drinking water Approach: Use dry comfortable fabric to wash the floor on the technique. If the procedure is dirty, moisten the smooth fabric with moderate soapy drinking water and wipe off any stains. Use dry comfortable cloth to remove any moisture and permit all really hard surfaces to absolutely air-dry. Site 146: Cleanse The Peripherals
Discover better diagnostic details by means of prolonged watch with the anatomical construction on all convex probes.
Assessing clients in right now’s demanding atmosphere calls for revolutionary technologies that enables clinicians to create fast and self-assured diagnoses. The versatility of your DP-fifty expands your medical utility while helping to strengthen client treatment.
five.two.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy Take a look at Move: Do changes as how in tests the most depth. History the distance by 20mm Just about every section within the longitudinal targets line utilizing the measurement caliper; Choose the worth with the greatest error (to 20mm), work out the accuracy utilizing the method under The measurement caliper needs to be positioned in the higher edge of the concentrate on, Notice:... Website page seventy nine Transverse geometric positioning precision Check Stage: Include the scan floor of the phantom with drinking water or few gel, Carefully Get hold of the probe Using the scan area Modify the depth, building the transverse targets being shown in the picture. Adjust the main target place to get posited beside the transverse targets (the regular will not be apparent) Alter parameters like achieve, TGC, creating each transverse targets to become Evidently shown. Webpage 80 5.5.2.4 Blackout Location Exam Phase: Address the scan Dp50rb login surface in the phantom with water or few gel, Carefully Get hold of the probe Along with the scan surface area Alter the depth at a reduced value, and established the focus at the closest location to the scan floor. Minimize the value of parameters like AP, Acquire right up until the background noise just can be seen. Webpage 81: Software Update And Upkeep
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Discover improved diagnostic details through extended watch with the anatomical composition on all linear probes
NOTE: Before inserting the connector in the probe port, inspect the connector pin. In the event the pin is bent, do not make use of the probe till it has been inspected / fixed / changed. Installing Peripherals For that models with the supported peripherals, please seek advice from “two.
Your Device for further biopsy: allowing adjustments on the scan line to realize better visibility in the needle, nerves and compact vessels, guaranteeing the continuity of all info.
Return on the system preset interface. The option standing changes into Uninstalled. The uninstalling purpose is exclusive to internal end users.